OMRON E2EL-X8E2-DM1S Price
No PHOTO
OMRON E2EL-X8E2-DM1S
Type: Low-sensitivity; 11-pin.
Space-saving Design Ideal for Control Panel.
Downsizing. Easy Maintenance.
Compact: 49.4 × 38 × 84 mm (H×W×D).
Easy identification of operating status with LED operation indicator.
Independent DPDT contacts on 11-Pin Models.
CE marking and UL/CSA compliance. Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application E2EL-X8E2-DM1S Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E2EL-X8E2-DM1S Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E2EL-X8E2-DM1S&select=5