Sensing method: BGS reflective (fixed distance).
Connection method: Connector (M8, 4 pins).
Sensing distance: 10 to 150 mm.
Model: PNP output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits.
Certified by Ecolab Europe
E2A-M12KN08-WP-B2 2M Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 10 m.
AC.
Minimum order: 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E2A-M12KN08-WP-B2 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2A-M12KN08-WP-B2 2M&select=5