R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 115V.
Allowable voltage range: 85 to 110% of rated voltage.
Frequency: 50/60Hz.
Rated current: 60Hz--0.175A; 50Hz--0.194A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB
82491-0190 MS46EPSR-30-350-Q1-
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - A16H-WR,
(protection structure IP65).
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
82491-0190 MS46EPSR-30-350-Q1- Operation manual/Instructions/Model selection sample download link: