Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.220 A; 60 Hz, 0.190 A .
Rated input: 50 Hz, 16 W; 60 Hz, 14 W.
Rated rotational speed: 50 Hz, 2350 r/min; 60 Hz, 2750 r/min.
Maximum flow rate: 50 Hz, 1.7 m3/min; 60 Hz, 2.0 m3/min.
Maximum static pressure: 50 Hz, 36.7 Pa; 60 Hz, 37.3 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 40 dB
82365-0020 UMDB-8
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: detection of variable terminal plate / DC type.
Shape: non shield.
Detection range: 30mm.
Output form: NO PNP + NC (dual output). Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.
82365-0020 UMDB-8 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=82365-0020 UMDB-8&select=5