Control cycle: one year.
Output number: 4 channel.
Installation: surface mount.
Power supply voltage: AC100 ~ 240V.
Japanese label model.
The new standard for use of more convenient timing switches.
On the basis of a week of 2 channel type, the output of 4 channel type / year type also joined the series.
Use the independent key to improve the working performance significantly.
Holiday, holiday and other output OFF have a simple holiday set function
70062-1053 SRU11
Power OFF can also be set.
Test mode that can be easily recognized by the program.
In accordance with UL/CSA, electrical safety standard certification, EMC standards.
Industry first
Can reduce the set value, achieve fast setting!
The built-in temperature compensation circuit, even in a larger temperature range,
Can also achieve high timing precisionAppearance: Round/Full-guard type A22-G.
Output: SPST-NO + SPST-NC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
70062-1053 SRU11 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70062-1053 SRU11&select=5