LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON 70060-1076 RKS12 Price
No PHOTO
OMRON 70060-1076 RKS12
Actuator: Roller plunger (Metal roller).
Cable length: 5 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 4NC (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available 70060-1076 RKS12
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. classification: Relay output.
I/O points: 16 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
70060-1076 RKS12 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=70060-1076 RKS12&select=5