Water Leak Alarm.
Flexible Setup according to Water Quality,
and Surrounding Wiring Conditions.
The operating resistance has a variable sensitivity from 0 to,
50 kΩ, so the best set values can be made according to the pre,
dicted water leakage, degree of overflow, water quality, or sur,
rounding wiring conditions.
The power supplied to the Sensing Band is 24 VAC, so opera,
tion is stable because there is no electrode deterioration from,
electrical corrosion
44512-0510 SB12-ALED10
A contact signal output enables monitoring from remote loca,
tions. Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 5 VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Actuator: Roller lever (metal lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, DPST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications.
44512-0510 SB12-ALED10 Operation manual/Instructions/Model selection sample download link: