LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON 44507-0392 MA-2DPC2 Price
No PHOTO
OMRON 44507-0392 MA-2DPC2
Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): Yes.
Rated input voltage: AC/DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape 44507-0392 MA-2DPC2
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.