Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 3.5 m3/min; 60 Hz, 4.0 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 50 dB; 60 Hz, 53 dB.
Weight: Approx. 3410 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
44507-0210 MA-1APC10
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available.
Compact design (31 × 30 × 30 mm) saves mounting space.
Easy-to-read red LED indicator.
Analog current output models available (E8Y-A@Y).
Pressure port Rc (PT) 1/8 models available (-R).
EN and UL approved. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
44507-0210 MA-1APC10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44507-0210 MA-1APC10&select=5