Type: DC-switching.
Contact form: 3PDT.
Open structure: Solder terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C
44501-3650 T5009-6022FSF1MM Ratings: 1 A at 30 VDC.
LED indicator: With indicator.
Actuator: Sealed pin plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
44501-3650 T5009-6022FSF1MM Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44501-3650 T5009-6022FSF1MM&select=5