Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
40259-5105 MP21Y-30-1050-RS
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: non shield, M30.
Detection distance: 20mm.
Action mode: NC. Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: Voltage input.
Operating mode(see note): Eight multi-modes: A, B, B2, C, D, E, G, J.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line.
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.
40259-5105 MP21Y-30-1050-RS Operation manual/Instructions/Model selection sample download link: