Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use
40252-7015 MP21Y-30-150-AS-R
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse to pulseApplication: General applications for purified water,
For 4-pole electrode (2-wire).
Separate Electrode Holders for Water.
Supply and Drainage Control in Buildings.
Small, Lightweight Electrode Holders for,
Use as Built-in Components.
The PS-@S(R) are separate Electrode Holders that allow the,
Electrodes to be withdrawn easily for inspection.
The PS-@S(R) come in 3, 4, or 5 pole models for supply and,
drainage of tap water in buildings.
PS-31 is a small and light-weight Electrode Holder that is,
suitable for installation in limited space and built-in components.
40252-7015 MP21Y-30-150-AS-R Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=40252-7015 MP21Y-30-150-AS-R&select=5