OMRON 3G2A5-OD411 Price
No PHOTO
OMRON 3G2A5-OD411
Display type: UP display timer (increments form 0 to the set time).
Output type: Contact output (SPDT).
Pin type: 11-pin.
Memory backup: provided.
Supply voltage: 100 to 240 VAC.
Rated time: 0.1 to 999.9 s.
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min 3G2A5-OD411
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. E3JK-R2M2 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 2.5m.
Output status: shading ON.
Output: relay,
2 types of cost reductionName: Clamp Terminal Blocks.
Specifications: Inputs; 16 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Models: DGR+OVGR.
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.
3G2A5-OD411 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=3G2A5-OD411&select=5


...more relevant model market price >>>>
Related products
OMRON
Triac Output Unit
C500-OA121(3G2A5-OA121)
OMRON Triac Output Unit C500-OA121(3G2A5-OA121)
C500-OA I/O Unit Triac Output 16 pts C50
OMRON
Output Unit
C500-OD212(3G2A5-OD212)
OMRON Output Unit C500-OD212(3G2A5-OD212)
C500-OD I/O Unit Transistor Output 32 pt
OMRON
Output Unit
C500-OD414(3G2A5-OD414)
OMRON Output Unit C500-OD414(3G2A5-OD414)
C500-OD I/O Unit Transistor Output 32 pt
OMRON
High-speed Counter Module
C500-CT001(3G2A5-CT001)
OMRON High-speed Counter Module C500-CT001(3G2A5-CT001)
C500-CT/3G2A5-CT Special I/O Unit High-s