Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.220 A; 60 Hz, 0.190 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB
D4A-3302N
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 30 mm.
Operation mode: Dark-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
D4A-3302N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4A-3302N&select=5