Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.9 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 41 Pa.
Noise: 50 Hz, 47 dB; 60 Hz, 48 dB.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
D40B-J1
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Shape: combination form.
Pole number: 60.
Pole pole number: 2.
Minimum packing unit: 30.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
D40B-J1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D40B-J1&select=5