I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits
CS1W-SLK21
DIN track mounting and screw mounting are both supported. Appearance: M5.
Sensing distance: 1.2 mm.
Connecting method: Pre-wired Models (2 m).
Cable specifications: PVC(oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: P5 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7.5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times.
Relay control output for circuit breaker switching.
Quality: about 0.5kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
CS1W-SLK21 Operation manual/Instructions/Model selection sample download link: