Type: General-purpose; 8-pin.
Space-saving Design Ideal for Control Panel.
Downsizing. Easy Maintenance.
Compact: 49.4 × 38 × 84 mm (H×W×D).
Easy identification of operating status with LED operation indicator.
Independent DPDT contacts on 11-Pin Models.
CE marking and UL/CSA compliance. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog (current/voltage)
CRT1-ROS08
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Action mode alarm contact: lock, B contact.
Category: no auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12). Name: Sensor.
Easy-to-use, Simple Magnetic.
Proximity Sensor.
Permanent magnetic used to operate the reed switch.
Ideal for detecting opening and closing of doors. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).