Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 3.9 m3/min; 60 Hz, 4.5 m3/min.
Maximum static pressure: 50 Hz, 86 Pa; 60 Hz, 56 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
A3SA-90B1-24EW
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 1NC/1NO+1NC/1NO.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
A3SA-90B1-24EW Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3SA-90B1-24EW&select=5