Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch
A3CA-90B1-28Y
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 41 dB; 60 Hz, 44 dB.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface,Open-loop control by,
pulse train output/Line-driver output;
Number of control axes, 2 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE.
High-speed, High-precision,
positioning with 1, 2, or 4 axes.
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.
A3CA-90B1-28Y Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3CA-90B1-28Y&select=5