Power supply voltage: 5 to 12 VDC.
Output configuration: NPN open collector.
Output code: BCD.
Resolution (divisions): 360.
Connection method: Pre-wired Connector Model (2 m) .
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection.
Strong shaft.
Radial: 120 N, Thrust: 50 N. Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units
A22W-2AG-12A-02
Specifications: I/O points, 8 inputs;
Input voltage and current: 12 to 24 VDC, 10 mA;
Commons, Independent contacts; External connection,
Removable terminal block; No. of words allocated, 1 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
A22W-2AG-12A-02 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22W-2AG-12A-02&select=5