Description: OS32C with EtherNet/IP and side location cable entry.
Max. Operating Range (Safety Zone): 3m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner
A22TK-2LR-21-03
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram. Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Product name: Split type CT, Connector: For connecting the branch cable,
Cable length: 0.2 m.
Power supply: Battery/DC cable.
Easy and Quick "Checking Power"at the Worksite. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A22TK-2LR-21-03 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22TK-2LR-21-03&select=5