Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 1 m.
AC.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
A22RL-TW-6A-10A
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Preset stage: 1-stage setting.
Nameplate lettering: English.
Nine Built-in Counters/Timers to.
Measure Equipment Operating.
Cycles and Times and Forecast.
Maintenance Timing.
Provides up to nine counters or accumulative timers.
(Counter and timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing.
Pre-forecast display and machine stoppage output provided.
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Key protection function prevents incorrect operation.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors.
Complies with UL and CSA. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Plastic rod.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
A22RL-TW-6A-10A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RL-TW-6A-10A&select=5