Control terminal block: Terminal block with small slotted screws.
Type: Standard.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current
A22R-TA-20A
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Column length 18mm, circle type F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Type: screw terminal type, small load without cable.
Rated current; 0.1A AC125V.
Driving rod: ball type.
Terminal: screw terminal without cable.
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.