Display type: DOWN display timer (decrements form the set time to 0).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC.
Rated time: 0.1 to 999.9 s.
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min
A22R-FW-20A
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Terminal: Screw terminal (-B).
Actuator: Hinge roller lever.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches. Specifications: Inputs;
NPN (+ common);
16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A22R-FW-20A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22R-FW-20A&select=5