Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement
A22L-HY-T1-02M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) (See note 2.).
Auxiliary output: None.
Functions: Heater burnout alarm, None; Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Ideal for water level control.
Sensitivity adjustment and timer for easy usage.
Sensitivity adjustment from 10 k to 100 kΩ.
Enables easy onsite adjustment.
ON-delay timer from 0.1 to 10 s.
Ideal as countermeasure for waves on liquid surfaces.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models with transistor outputs added for low contact wear.
A22L-HY-T1-02M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-HY-T1-02M&select=5