Brand Sort: OMRON
Home >> Price
OMRON A22L-HG-24A-01M Price
OMRON A22L-HG-24A-01M
Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance A22L-HG-24A-01M
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000).
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.


A22L-HG-24A-01M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A22L-HG-24A-01M&select=5


...more relevant model market price >>>>
Related products
OMRON
Pushbutton Switch
A22L-HG-T1-01M
OMRON Pushbutton Switch A22L-HG-T1-01M
Appearance: Round/Half-guard type LED vo
OMRON
Pushbutton Switch
A22L-DA-24A-01M
OMRON Pushbutton Switch A22L-DA-24A-01M
Appearance: Square/Projection type LED l
OMRON
Pushbutton Switch
A22L-HY-24A-01M
OMRON Pushbutton Switch A22L-HY-24A-01M
Appearance: Round/Half-guard type LED li
OMRON
Pushbutton Switch
A22L-HG-T2-11M
OMRON Pushbutton Switch A22L-HG-T2-11M
Appearance: Round/Half-guard type LED vo