Size: 72 x 72mm.
Type: Platinum resistance.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Type: screw terminal type, general type without cable
MY4-02 DC24
Rated current; 5A AC125V.
Drive rod: plunger type.
Terminal: screw terminal without cable.
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Control cycle: Yearly.
Number of outputs: 4 circuits.
Mounting method: Surface mounting/track mounting.
Supply voltage: 100 to 240 VAC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank function allows program switching by an external input.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.