Project: Japanese specification model.
Installation method: surface /DIN rail installation (agreement type) horizontal.
All day control operation is simple
Can be carried out on the choice of a few weeks of action. (but only 1 of the week moves and all week specific dates can be set)
ON/OFF time setting has 24 steps.
Consistent with CE markers. Through the UL, CSA standard certification.
Rest day function can be easily carried out on holidays, such as the setting of a sudden break
MTKC-1000-1250
Test mode function can easily confirm the program.
Can also be used to deal with a sudden change in the way of a semi automatic work.
The pulse action can cope with daylight saving time.
All models are equipped with finger protection function.
Product series contains embedded installation, surface mount, the size of the agreement and other ways.
The same setting can be done with the timer action. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
MTKC-1000-1250 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MTKC-1000-1250&select=5