Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000.0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000
MM3XB DC240 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: non shield, M12.
Detection range: 5mm.
Output configuration: PNP.
Action mode: NO. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Name: On-site Flexible Rod Switch (with separable emergency stop switch).
Mounting method: Front mounting.
Easy on-site input on-the-move.
Incorporation of plastic rod actuator makes the Switch easy on hands.
One-way operation:
Equipped with stopper so that operation is only possible from one direction.
Distinctive yellow used for the body.
Three different types of mounting are available.
Models with emergency-stop switch are available to suit the application. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
MM3XB DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MM3XB DC24&select=5