Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
MKS3PN-5 AC100
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: Cycle Control Unit.
Isolation transformer: Yes.
Rated power supply voltage: 100 to 240 VAC.
Refer to Safety Precautions for All Power Controllers.
Used in Combination with the G3PA to.
Enable High-precision Temperature Contro.
Use cycle control to achieve power control with little noise.
Used in combination with the G3PA to connect to single- and,
three-phase loads.
Three types of input method available: Internal adjuster,
external adjuster, or DC signals from 4 to 20 mA.
Streamline design. Both DIN track mounting and screw,
mounting possible.
Use linking terminals for close mounting of the G3PA.
Built-in isolation transformer.
Power supply range: 100 to 240 V. Number of beams: 78.
Protective height: 1560mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Cable length L: 1.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input
MKS3PN-5 AC100 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS3PN-5 AC100&select=5