LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON MKS3PI-V AC6 Price
No PHOTO
OMRON MKS3PI-V AC6
Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: DPDT.
Lighting: Incandescent lamp, 28 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation MKS3PI-V AC6
Easy panel mounting from the front and simple lamp replacement.
without tools. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Function name: 3 phase 400V.
Power: 0.4KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.5KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):143.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
MKS3PI-V AC6 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=MKS3PI-V AC6&select=5


...more relevant model market price >>>>
Related products
OMRON
General-purpose Relays
MKS3PIN
OMRON General-purpose Relays MKS3PIN
Type: Models with LED Indicator See not
OMRON
General-purpose Relays
MKS3PI
OMRON General-purpose Relays MKS3PI
Type: Models with LED Indicator See not
OMRON
General-purpose Relays
MKS3PIN1
OMRON General-purpose Relays MKS3PIN1
Type: Models with LED Indicator See not
OMRON
General-purpose Relays
MKS3PI-2
OMRON General-purpose Relays MKS3PI-2
Type: Models with LED Indicator See not