Model: C500-BC052(3G2A5-BC052).
5 slots(5 linkable slots).
Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry
MK3P DC6
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: Laser Reflectors, Sheets.
Ambient operating temperature range: -10 to 55°C (No icing and no condensation).
Ambient storage temperature range: -25 to 70°C (No icing and no condensation).
Ambient operating humidity range: 35 to 85% (No condensation).
Ambient storage humidity range: 35 to 85% (No condensation). Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 3.9 m3/min; 60 Hz, 4.5 m3/min.
Maximum static pressure: 50 Hz, 86 Pa; 60 Hz, 56 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, High-sensitivity, Low-torque.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
MK3P DC6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MK3P DC6&select=5