Type: Shielded.
Appearance: Flat, 30 × 14 × 4.8 mm.
Sensing distance: 5 mm.
Repeat accuracy: 2 μm.
Cable specification: With Protective Spiral Tube.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads
M7F-4N2RT
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Input type: Platinum-resistance thermometer or thermocouple.
Supply voltage: 24 VAC/VDC.
Output: None.
Highly Visible LCD Display with 2-color (Red and Green) LEDs.
Wide input range - select from two types of platinum-resistance,
thermometers and ten types of thermocouples.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Temperature input shift and temperature unit selection functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) protects against,
electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to conform to U.S. and Canadian requirements under,
the Component Recognition Program of UL.
CE marking. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
M7F-4N2RT Operation manual/Instructions/Model selection sample download link: