Measuring current: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load)
LY2-0-J AC200/220
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Item: Advanced models, ATC function.
Functions: ATC (Active Threshold Control).
Model: NPN output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Product name: CJ2H CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 250K steps; Data memory capacity,
512K words(DM: 32K words, EM: 32K words × 15 banks);
LD nstructio execution time, 0.016 μs.
Current consumption(A): 5V,0.42(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity.
The CJ2H Series is ideal for advanced machine.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 25 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).
LY2-0-J AC200/220 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LY2-0-J AC200/220&select=5