Model: CPM2C-32EDTC. Units with 32 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Control supply voltage: 100/ 200 VAC; Without voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal
K3NC-NB1A-FLK1
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Digital universal dual display electronic temperature controller.
DIN 48 * 48mm manual automatic tuning (Auto-tuning Manual) PID control.
Double alarm / single alarm and temperature resistance antibody species rich.
Relay / solid state relay (SSR drive) series.
To prevent misuse function. "Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: DPDT.
Lighting: Incandescent lamp; 14 VDC/VAC.
Pushbutton color symbol: 2.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-422.
Input type: No input.
Terminal: M3 terminal .
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.
K3NC-NB1A-FLK1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NC-NB1A-FLK1&select=5