Name: Heat/Cool Temperature Control Module.
Model: C200H-TV002.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Voltage output(transistor output used for cooling outputs).Actuator: Plastic rod.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms
K2CM-Q2LA
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. CV500-CN Cable Motion Control Connecting Cables 6 m CV500-CN624Power supply voltage: 5 to 12 VDC.
Output configuration: NPN open collector.
Output code: BCD.
Resolution (divisions): 360.
Connection method: Pre-wired Model.
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection.
Strong shaft.
Radial: 120 N, Thrust: 50 N. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
K2CM-Q2LA Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K2CM-Q2LA&select=5