I/O classification: Analog input.
I/O points: 8.
I/O connections: Molex connector.
Power supply voltage: 24 VDC.
I/O specification: 4 to 20 mA, 0 to 20 mA, 0 to 5 V,
1 to 5 V, 0 to 10 V, -10 to 10 V.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outputs
H3CR-F8N-300 AC100-240
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 50W.
Output voltage: 12V.
Output current: 4.3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"Suitable cable dia: 3 mm dia. model (3 to 4 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Crimping.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
H3CR-F8N-300 AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H3CR-F8N-300 AC100-240&select=5