Number of beams: 26.
Protective height: 545mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit)
XW2Z-100J-B2
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NO + SPST-NC.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Type: Side-view lens.
Spot: Spot dia.: 8 mm.
Cost Revolution Led by UV Curing.
System.
Minimal heat damage thanks to UV-LED irradiation.
New UV LEDs with much higher brightness mounted in heads.
Greater irradiation power to reduce bonding tact time.
Usage of LEDs that have a long lifetime of 40,000,
hours* drastically reduces running costs.
Ultra compact body that is approximately 1/8th the size,
of a conventional lamp system.
Equipped with a color LCD that makes settings simple and reliable. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.