Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-485;
or RS-232C, selectable
XW2R-J50G-T
Input type: No input.
Terminal: M3 terminal .
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (general purpose).
Inner diameter (D)of seal rubber: 14 mm.
External diameter of cable: Min, 12 mm; Max, 14 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.
XW2R-J50G-T Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=XW2R-J50G-T&select=5