Actuator: Roller lever: R38.
Wiring specification: NO wiring.
Item: Molded terminals, -139 models; High-precision.
Pretravel (PT): 5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability
XG5W-0231
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is the,
Same Shape as 16-point Remote I/O Terminals.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D). Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
Series of DeviceNet type.
UL standard applicable certification (identity certificationSmall 4 point output terminal relay with C contact relay.
Built in 4 G6B-2114P-US.
LED with action indication.
Diode built-in surge absorber.
Socket special, so the replacement of the relay is simple.
DIN guide rail installation, screw mounting common. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.
XG5W-0231 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XG5W-0231&select=5