Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations
XG4A-1434
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Model: C200H-MAD01.
External input points: 2.
External output points: 2.
External input signal range: 1 to 5 V or 0 to 10 V or –10 to 10 V.
External output signal range: 1 to 5 V or 0 to 10 V or –10 to 10 V.Number of beams: 76.
Protective height: 1520mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
XG4A-1434 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XG4A-1434&select=5