Dimensions: A, 1000mm; B, 500mm.
Model: Black.
Safety outputs: SPDT-NO.
Auxiliary outputs: SPDT-NC.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
New Safety Mat That Is Easy to.
Install and Maintain.
Simple connection allows multiple mats to be joined together.
A wide variety of mat sizes are available.
Obtained EN1760-1 and EN ISO13849-1 (PLd/Safety.
Category 3) certification
WLCA2-2TC-N
Complies with North American safety standards,
including ANSI/RIA15.06-1999. Appearance: Rectangular (M16-T).
Lighting: Incandescent lamp, 12 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Shape: round.
Protection structure: IP40.
Action: alternate.
Operation Department color: yellow.
Column length 18mm, circular F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: SPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Appearance: Standard sound.
w/jumper direction A *2: Intermittent.
w/jumper direction B *2(w/o jumper): Continuous.
Supply voltage: 6 VAC/VDC.
Buzzer Unit Series with Cylindrical.
22-mm × 16-dia. Body.
Lineup includes standard-volume models (80 phons, constant) and,
high-volume models (70 to 95 phons, variable). Intermittent or,
continuous sound can be selected. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
WLCA2-2TC-N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLCA2-2TC-N&select=5