Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection
WL-2A122 The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Type: Welding / wire type, with left column.
Drive rod: R blade Shibai rod type.
Terminal specifications: with wire, the left side.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
WL-2A122 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WL-2A122&select=5