Specification: Four contacts, no mounting bracket, no rubber seal.
3-position Enabling Switch for Safer.
Robot Operation.
Clicking feel.
Conforms to U.S. standards (ANSI/RIA R15.06-1999) for.
3-position switches.
Can be mounted in two directions. Description: Four line LCD with RS232C port +RS485 port.
Perfect support CP1E.
Quality and price are full of confidence,
Perfect solution for OEM equipment such as air conditioning system, water supply system and so on
UMM5-0300-1250
The size is fixed to 16 x 16 round or square lamp,
Dynamic object that can display the bright or dark figure according to the PLC bit state.
The content change of PLC channel is monitored in real time in the form of bar chart,
And can set the direction of change and define the value of 100%. classification: Power MOS FET relay output.
I/O points: 16 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
UMM5-0300-1250 Operation manual/Instructions/Model selection sample download link: