Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Black.
Output: SPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup
TL-W5MC2 2M Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 150W.
Output voltage: 15V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit.
For 2 Unit.Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
TL-W5MC2 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=TL-W5MC2 2M&select=5