Type: rectangle.
Screen mode: 2 short axis segmentation.
Light way: LED.
Power supply voltage: 28V
Operating part left color: blue.
Operation Department right color: green.
Square 40mm body of the indicator light series.
The same type as the A3S series button switch.
Easy to install from the front panel and no tools to carry out the lamp replacement. Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H
TL-W3MC15 2M
Output: SPST-NO.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Detection methods: on the radio type (projector + optical device).
Connection: socket type (M12).
Detection distance: infrared 20m.
Output mode: NPN output.
Optical projector: 2M E3Z-FTN22-L.
Optical device: 2M E3Z-FTN22-D. Number of beams: 46.
Protective height: 920mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. CompoNet sensor communication unit, simplify sensor settings and management.
No program can be transmitted to the ON/OFF signal PLC (CompoNet communication from the station function).
Support setting content to the detection threshold, quantity and function of reading, writing and teaching operation (explicit message function).
The assembly is simple, just use the communication cable to connect the E3X-CRT and the amplifier next to it.
Up to 16 sensor amplifiers can be connected.
TL-W3MC15 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=TL-W3MC15 2M&select=5