LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON SGE-365-3-1520 00750M-01200F Price
No PHOTO
OMRON SGE-365-3-1520 00750M-01200F
Number of beams: 41.
Protective height: 1020mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 200V SGE-365-3-1520 00750M-01200F
Allowable voltage range: 85 to 110% of rated voltage.
Frequency: 50/60Hz.
Rated current: 60Hz--0.098A; 50Hz--0.109A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - A16H-WR,
(protection structure IP65).
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: P5 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7.5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times.
Relay control output for circuit breaker switching.
Quality: about 0.5kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.