LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON SGE-365-2-2450 01000C Price
No PHOTO
OMRON SGE-365-2-2450 01000C
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.028 A; 60 Hz, 0.024 A .
Rated input: 50 Hz, 5 W ; 60 Hz, 4 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2100 r/min.
Maximum flow rate: 50 Hz, 0.4 m3/min; 60 Hz, 0.5 m3/min.
Maximum static pressure: 50 Hz, 19.5 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 28 dB; 60 Hz, 30 dB SGE-365-2-2450 01000C
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
SGE-365-2-2450 01000C Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=SGE-365-2-2450 01000C&select=5


...more relevant model market price >>>>