Appearance: Shielded, 3 dia.
Sensing distance: 0.5 mm.
Model: Output configuration, NPN open-collector output; NO.
Subminiature Sensors with.
Long-distance Detection.
Shielded Sensor Heads from 3-mm to M12 diameters that,
can be embedded in metal.
Robotics cables provided as a standard feature (DC 2-Wire Models).
Indicator provided in Amplifier cable for easy confirmation of operation.
Power supply range of 5 to 24 VDC for DC 3-Wire Models
S8JC-ZS15005C-AC2 Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Output voltage: 5 V.
Output current: 5 A.
Connector terminal Model (See note 3.): Without Bus Line Connectors (See note 2.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels).
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models).
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable.)
Operating temperatures to –20°C (24-V models).
S8JC-ZS15005C-AC2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8JC-ZS15005C-AC2&select=5