Appearance: Unshielded, M18.
Sensing distance: 10 mm [6 to 10 mm *].
Output Model: DC 3-wire NPN.
Operation mode: NC.
Fluororesin-coated Capacitive.
Sensor with Sensitivity Adjuster.
Excellent resistance against chemicals and oil with fluororesin,
coated case.
Distance adjustment according to the sensing object using the,
sensitivity adjuster. Model: C200H-OD214.
No. of points: 8 pts.
Specifications: 0
S8FS-C150058 A, 24 VDC. source type (PNP). with load short protection.Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
S8FS-C15005 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8FS-C15005&select=5